Weather station
Davis Vantage Pro2 Plus
Davis Vantage Pro2 Plus 24 hour fan aspirated
ISS (integrated sensor suite) is equipped with rain collector, temperature and humidity sensors, anemometer, solar radiation sensor, and UV sensor. ISS is solar powered. Temperature and humidity sensors are enclosed in a solar-powered, 24-hour fan-aspirated radiation shield. Shield combines fan aspiration and passive shielding to minimize the effects of solar radiation. Using seperate Anemometer solar powered transmitter, which allows me to mount anemometer away from ISS.
|
|
Range. . . . . . . . . . . . . . . . . . .-40° to +150°F
Sensor Accuracy. . . . . . . . . . ±1°F up to 110°F, ±2°F over 110°F
Update Interval . . . . . . . . . . . 10 to 12 seconds to console |
|
Range. . . . . . . . . . . . . . . . . . . . . . .1 to 100% RH
Accuracy. . . . . . . . . . . . . . . . . . . . ±3% (0 to 90% RH), ±4% (90 to 100% RH)
Temperature Coefficient . . . . . . . 0.03% per °F (0.05% per °C), reference 68°F (20°C)
Drift . . . . . . . . . . . . . . . . . . . . . . . . ±0.5% per year
Update Interval . . . . . . . . . . . . . . . 50 seconds to 1 minute to console |
|
Located inside console
Resolution and Units. . . . . . . . . . . .0.01" Hg, 0.1 mm Hg, 0.1 hPa/mb (user-selectable) |
|
Range (large wind cups) . . . . . . . ..2 to 150 mph, 2 to 130 knots, 1 to 67 m/s, 3 to 241 km/h
Accuracy (large wind cups) . . . . . .±2 mph (2 kts, 3 km/h, 1 m/s) or ±5%, whichever is greater
Update Interval . . . . . . . . . . . . . . . .Instant Reading: 2.5 to 3 seconds, 10-minute Average: 1 minute; to console |
|
Display Resolution . . . . . . . . . . . . 16 points (22.5°) on compass rose, 1° in numeric display
Accuracy . . . . . . . . . . . . . . . . . . . . ±7°
Update Interval . . . . . . . . . . . . . . . 2.5 to 3 seconds to console |
|
Resolution and Units . . . . . . . . . . . . . . . . .0.01" or 0.25 mm (user-selectable) (1 mm at totals ≥ 2000 mm)
Daily/Storm Rainfall Range . . . . . . . . . . . .0 to 99.99" (0 to 9999 mm)
Monthly/Yearly/Total Rainfall Range. . . . .0 to 199.99" (0 to 19999 mm)
Rain Rate. . . . . . . . . . . . . . . . . . . . . . . . . . .0 to 199.99" (0 to 19999 mm)
Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . .For rain rates up to 2"/hr (50 mm/hr): ±4% of total or +0.01" (0.25 mm)
(0.01" = one tip of the bucket), whichever is greater
For rain rates from 2"/hr (50 mm/hr) to 4"/hr (100 mm/hr): ±5% of total or
+0.01" (0.25 mm) (0.01" = one tip of the bucket), whichever is greater
Update Interval . . . . . . . . . . . . . . . . . . . . . . 10 to 12 seconds to console |
|
Resolution and Units . . . . . . . 1 W/m2
Range . . . . . . . . . . . . . . . . . . . 0 to 1800 W/m2
Accuracy . . . . . . . . . . . . . . . . .±5% of full scale (Reference: Eppley PSP at 1000 W/m2)
Update Interval . . . . . . . . . . . 50 seconds to 1 minute (5 minutes when dark) to console
|
|
Resolution and Units . . . . . . . . . 0.1 Index
Range . . . . . . . . . . . . . . . . . . . . . 0 to 16 Index
Accuracy . . . . . . . . . . . . . . . . . . .±5% of full scale (Reference: Yankee UVB-1 at UV index 10 (Extremely High))
Update Interval . . . . . . . . . . . . . .50 seconds to 1 minute (5 minutes when dark) to console |
|